Agglomeration view on a map with some info UWWTP : UWWTP TWEEDE EXLOERMOND - Identifier : NL03023 - Status : Active - Connected - Reporting year : 2016 Region (NUTS) Code : NL132 - Region (NUTS) Name : Zuidoost-Drenthe compliance Time Line List of all the year available for the agglomeration 2012201420162018View history Compliant Not compliant Not relevant No information ? Description Load entering UWWTP (p.e.): load expressed in population equivalent shall be calculated on the basis of the maximum average weekly load entering the treatment plant during the year, excluding unusual situations such as those due to heavy rain (Article 4 of the Urban Waste Water Treatment Directive 91/271/CE)9 200Method used to determine the load : Not availableRate of entering load transported to this UWWTP by trucks (%): Not availablePhysical Capacity (p.e.): 8 417Waste water treated (m3/y): Volume of waste water treated and partially treated in the UWWTPNot availableMethod used to determine the volume of waste water treated: Not availableTreatment performance: BOD5: Biological Oxygen DemandPassTreatment performance: COD: Chemical Oxygen DemandPassTreatment performance: TSS: Total Suspended SolidsNRTreatment performance: Total nitrogen: Sum of total kjeldahl nitrogen (organic, ammonia and ammonium), nitrate and nitriteNRTreatment performance: Total phosphorus: Sum of dissolved phosphorus and insoluble phosphorusNRTreatment performance: Other: e.g. e-coliCompliance: CompliantTreatment type in place: More stringent treatmentTreatment required: Secondary treatmentTreatment met: YesPerformance met: YesIn cause of failure: Bad operating/Bad design or dimensioning: 0In cause of failure: Bad design or dimensioning: 0In cause of failure: Further information on cause of failure: Not available Load and concentration per parameter : Incoming Discharged Rate BOD 201.48 t/year 8.03 t/year 96% COD 444.21 t/year 49.28 t/year 88.9% Nitrogen 29.57 t/year 7.3 t/year 75.3% Phosphorus 4.75 t/year 1.46 t/year 69.3% * Concentration calculated using the annual load and the annual volume of wastewater treated. Incoming and discharged loads (t/year) Graphical network summary Agglomerations : 1 Agglomeration : 2E EXLOERMOND (Generated UWWTP TWEEDE EXLOERMOND Entering :9,200 p.e NP 1 DCP(S)Discharge point: DISCHARGE POINT UWWTP TWEEDE EXLOERMONDNetherlands(A58) Main treatment : : Compliant : Not compliant : No information / Not relevant More stringent treatment : Performance : : Pass performance : Fail performance : Not relevant Type : N : Nitrogen removal P : Phosphorus removal UV : UV treatment MICRO : Micro Filtration Type : CHLOR : Chlorination OZONE : Ozonation SAND : Sand filtration O : Other more stringent Discharge point : : Discharge point DCP(S) : Discharge point(s) Waste Water Network Connexions Linked agglomeration(s): 2E EXLOERMONDLinked receiving area(s): NetherlandsLinked discharge point(s): DISCHARGE POINT UWWTP TWEEDE EXLOERMOND Site information Year of data: 2016 Source of data: See sourcefile Other years : Year of data: 2018 Source of data: See sourcefile Year of data: 2014 Source of data: See sourcefile Year of data: 2012 Source of data: See sourcefile UWWTP national Internet hyperlink: Not available Characteristics Latitude : 52.91716666 Longitude : 6.94965000 Date of closing: Explanation for closing: ID of the successor: Not providedPrimary treatment: Secondary treatment: N removal: P removal: UV: Ozonation: Sand filtration: Chlorination: Micro filtration: Other treatment: Other type of more stringent treatment: Other type of more stringent : Not providedID of E-PRTR facility: Not providedAccidents: Remarks: