Beta Version : remaining inconsistencies are possible. They will be corrected during the next reporting exercise

UWWTP BEILEN - history

UWWTP : UWWTP BEILEN - Identifier : NL03001 - Status : Active
Region (NUTS) Code : NL131 - Region (NUTS) Name : Noord-Drenthe

2012

2014

2016

2018

 
Compliant
 
Not compliant
 
Not relevant
 
No information
 
?


Description

YearComplianceTreatment typeLoadTreatment performance
2012Compliance : ?
Treatment met : No
Performance met : No
required :
in place : More stringent treatment
Capacity:
59,670 p.e.From field <uwwCapacity> : Organic design capacity (p.e.)
Entering:
35,783 p.e.From field <uwwLoadEnteringUWWTP> : Load entering UWWTP (p.e.)
Load rate:
60 % underload<uwwLoadEnteringUWWTP> / <uwwCapacity> x 100
BOD:
PassFrom field <uwwBOD5Perf>
COD:
PassFrom field <uwwCODPerf>
TSS:
Not relevantFrom field <uwwTSSPerf>
Total Nitrogen:
Not relevantFrom field <uwwNTotPerf>
Total phosphorus:
Not relevantFrom field <uwwPTotPerf>
2014Compliance : Compliant
Treatment met : Yes
Performance met : Yes
required : Secondary treatment
in place : More stringent treatment
Capacity:
59,670 p.e.From field <uwwCapacity> : Organic design capacity (p.e.)
Entering:
46,473 p.e.From field <uwwLoadEnteringUWWTP> : Load entering UWWTP (p.e.)
Load rate:
77.9 % <uwwLoadEnteringUWWTP> / <uwwCapacity> x 100
BOD:
PassFrom field <uwwBOD5Perf>
COD:
PassFrom field <uwwCODPerf>
TSS:
Not relevantFrom field <uwwTSSPerf>
Total Nitrogen:
Not relevantFrom field <uwwNTotPerf>
Total phosphorus:
Not relevantFrom field <uwwPTotPerf>
2016Compliance : Compliant
Treatment met : Yes
Performance met : Yes
required : Secondary treatment
in place : More stringent treatment
Capacity:
59,670 p.e.From field <uwwCapacity> : Organic design capacity (p.e.)
Entering:
55,417 p.e.From field <uwwLoadEnteringUWWTP> : Load entering UWWTP (p.e.)
Load rate:
92.9 % <uwwLoadEnteringUWWTP> / <uwwCapacity> x 100
BOD:
PassFrom field <uwwBOD5Perf>
COD:
PassFrom field <uwwCODPerf>
TSS:
Not relevantFrom field <uwwTSSPerf>
Total Nitrogen:
Not relevantFrom field <uwwNTotPerf>
Total phosphorus:
Not relevantFrom field <uwwPTotPerf>
2018Compliance : Compliant
Treatment met : Yes
Performance met : Yes
required : Secondary treatment
in place : More stringent treatment
Capacity:
59,670 p.e.From field <uwwCapacity> : Organic design capacity (p.e.)
Entering:
50,501 p.e.From field <uwwLoadEnteringUWWTP> : Load entering UWWTP (p.e.)
Load rate:
84.6 % <uwwLoadEnteringUWWTP> / <uwwCapacity> x 100
BOD:
PassFrom field <uwwBOD5Perf>
COD:
PassFrom field <uwwCODPerf>
TSS:
Not relevantFrom field <uwwTSSPerf>
Total Nitrogen:
Not relevantFrom field <uwwNTotPerf>
Total phosphorus:
Not relevantFrom field <uwwPTotPerf>

Entering load and design capacity

Entering load vs Physical Capacity (p.e.)
See the data table
Entering load vs Physical Capacity (p.e.)
See diagram
YearEnteringCapacityLoad rate
201235,783 p.e.59,670 p.e.60 % underload
201446,473 p.e.59,670 p.e.77.9 %
201655,417 p.e.59,670 p.e.92.9 %
201850,501 p.e.59,670 p.e.84.6 %

COD & BOD

COD load entering and discharged (Tons per year)
See the data table
COD load entering and discharged (Tons per year)
See diagram
YearEnteringDischargedPerformance rate
20120 T/y0 T/y-
20140 T/y0 T/y-
20162,816 T/y122 T/y95.7 %
20182,461 T/y121 T/y95.1 %
BOD load entering and discharged (Tons per year)
See the data table
BOD load entering and discharged (Tons per year)
See diagram
YearEnteringDischargedPerformance rate
20120 T/y0 T/y-
20140 T/y0 T/y-
20161,214 T/y9 T/y99.3 %
20181,106 T/y11 T/y99.0 %

Nitrogen & Phosphorus

Nitrogen load entering and discharged (Tons per year)
See the data table
Nitrogen load entering and discharged (Tons per year)
See diagram
YearEnteringDischargedPerformance rate
20120 T/y0 T/y-
20140 T/y0 T/y-
2016189 T/y18 T/y90.4 %
2018188 T/y21 T/y89.0 %
Phosphorus load entering and discharged (Tons per year)
See the data table
Phosphorus load entering and discharged (Tons per year)
See diagram
YearEnteringDischargedPerformance rate
20120 T/y0 T/y-
20140 T/y0 T/y-
201650 T/y2 T/y95.8 %
201835 T/y3 T/y92.3 %

Agglomerations

Year
UWWTP capacity
Value define in <uwwCapacity> field for the UWWTP in the report file with definition : "Organic design capacity (p.e.)"
UWWTP Entering load
Value define in <uwwLoadEnteringUWWTP> field for the UWWTP in the report file with definition : "Load entering UWWTP (p.e.)"
Total of load collected by collecting systems and entering the UWWTPs
Sum of load adressed to UWWTP by linked agglomeration. The load addressed by an agglomeration to an UWWTP is calculated with the following formula : Generated load (p.e.) of the agglomeration (<aggGenerated>) x Rate of generated load of agglomeration collected through collecting system (% of p.e.) (<aggC1>) x % of load of agglomeration collected in collecting system and entering that treatmentplant (<aucPercEnteringUWWTP>)
Linked Agglomeration(s) with addressed load to the UWWTP
201259,670p.e.35,783p.e.36,249p.e.
201459,670p.e.46,473p.e.47,077p.e.
201659,670p.e.55,417p.e.56,137p.e.
201859,670p.e.50,501p.e.51,158p.e.
Notice : "UWWTP entering load" is based on measure of yearly average, "Total of load collected" is based on estimation of maximum over a year.

Discharge points

  • There is a change in number of elements between 2012 and 2014
  • There are new elements between 2012 and 2014: NLDP03001.
YearLinked Discharge point(s)
2012
2014
2016
2018