See diagram
Sant Antnin Urban Wastewater Treatment Plan | European Commission urban waste water website: Malta
Beta Version : remaining inconsistencies are possible. They will be corrected during the next reporting exercise

Sant Antnin Urban Wastewater Treatment Plan

Agglomeration view on a map with some info

UWWTP : Sant Antnin Urban Wastewater Treatment Plan - Identifier : MTSASTP - Status : Active - Connected - Reporting year : 2014
Region (NUTS) Code : MT001 - Region (NUTS) Name : Malta

compliance Time Line
List of all the year available for the agglomeration

2014

2016

2018

 
Compliant
 
Not compliant
 
Not relevant
 
No information
 
?


Description
Load entering UWWTP (p.e.): 
load expressed in population equivalent shall be calculated on the basis of the maximum average weekly load entering the treatment plant during the year, excluding unusual situations such as those due to heavy rain (Article 4 of the Urban Waste Water Treatment Directive 91/271/CE)
24 667
Method used to determine the load : 
Not available
Rate of entering load transported to this UWWTP by trucks (%): 
Not available
Physical Capacity (p.e.): 
120 000
Waste water treated (m3/y): 
Volume of waste water treated and partially treated in the UWWTP
1 649 191
Method used to determine the volume of waste water treated: 
M
Treatment performance: BOD5: 
Biological Oxygen Demand
Pass
Treatment performance: COD: 
Chemical Oxygen Demand
Pass
Treatment performance: TSS: 
Total Suspended Solids
Pass
Treatment performance: Total nitrogen: 
Sum of total kjeldahl nitrogen (organic, ammonia and ammonium), nitrate and nitrite
NR
Treatment performance: Total phosphorus: 
Sum of dissolved phosphorus and insoluble phosphorus
NR
Treatment performance: Other: 
e.g. e-coli
NR
Compliance: 
?
Treatment type in place: 
More stringent treatment
Treatment required: 
NI
Treatment met: 
No
Performance met: 
No
In cause of failure: Bad operating/Bad design or dimensioning: 
0
In cause of failure: Bad design or dimensioning: 
0
In cause of failure: Further information on cause of failure: 
Not Applicable
See diagram

Load and concentration per parameter :

Incoming Discharged Rate
BOD 562 t/year 14 t/year 97.5%
340.77 mg/l 8.49 mg/l
COD 1368 t/year 204 t/year 85.1%
829.5 mg/l 123.7 mg/l
Nitrogen 0 t/year
Phosphorus 0 t/year
* Concentration calculated using the annual load and the annual volume of wastewater treated.
Incoming and discharged loads (t/year)
See the data table
Graphical network summary
Network
Agglomerations : 1 Agglomeration : Malta South
(Generated
Network
Network
CHLOR
Network
SAND
Network
reseau
0 DCP(S)
Discharge point:
    Main treatment :
  • Network : Compliant
  • Network : Not compliant
  • Network : No information / Not relevant
    More stringent treatment :
    Performance :
  • Network : Pass performance
  • Network : Fail performance
  • Network : Not relevant

    Type :
  • N : Nitrogen removal
  • P : Phosphorus removal
  • UV : UV treatment
  • MICRO : Micro Filtration

    Type :
  • CHLOR : Chlorination
  • OZONE : Ozonation
  • SAND : Sand filtration
  • O : Other more stringent
    Discharge point :
  • Network : Discharge point
  • DCP(S) : Discharge point(s)
Waste Water Network Connexions
Linked agglomeration(s): 
Linked receiving area(s): 
Not available
Linked discharge point(s): 
Not available
Site information
Characteristics
 35.86000000
 14.55000000
Date of closing: 
NR
Explanation for closing: 
NR
ID of the successor: 

Not provided

Primary treatment: 
Yes
Secondary treatment: 
Yes
N removal: 
No
P removal: 
No
UV: 
No
Ozonation: 
No
Sand filtration: 
Yes
Chlorination: 
Yes
Micro filtration: 
No
Other treatment: 
No
Other type of more stringent treatment: 
Not applicable
Other type of more stringent : 
0
ID of E-PRTR facility: 

Not provided

Accidents: 
No
Remarks: 
Plant has been temporarily retained in operation to supplement the capacity of the Ta' Barkat plant.