See diagram
salcininku aglomeracija | UWWTD SIIF Lithuania National Node
Beta Version : remaining inconsistencies are possible. They will be corrected during the next reporting exercise

salcininku aglomeracija

Agglomeration view on a map with some info

UWWTP : salcininku aglomeracija - Identifier : LT-AG-046-WWTP-01 - Status : Active - Connected - Reporting year : 2014
Region (NUTS) Code : LT00A - Region (NUTS) Name : Vilniaus apskritis

compliance Time Line
List of all the year available for the agglomeration

2011

2014

2016

2018

 
Compliant
 
Not compliant
 
Not relevant
 
No information
 
?


Description
Load entering UWWTP (p.e.): 
load expressed in population equivalent shall be calculated on the basis of the maximum average weekly load entering the treatment plant during the year, excluding unusual situations such as those due to heavy rain (Article 4 of the Urban Waste Water Treatment Directive 91/271/CE)
9 500
Method used to determine the load : 
Not available
Rate of entering load transported to this UWWTP by trucks (%): 
Not available
Physical Capacity (p.e.): 
8 400
Waste water treated (m3/y): 
Volume of waste water treated and partially treated in the UWWTP
443 700
Method used to determine the volume of waste water treated: 
M
Treatment performance: BOD5: 
Biological Oxygen Demand
Pass
Treatment performance: COD: 
Chemical Oxygen Demand
Pass
Treatment performance: TSS: 
Total Suspended Solids
NR
Treatment performance: Total nitrogen: 
Sum of total kjeldahl nitrogen (organic, ammonia and ammonium), nitrate and nitrite
Pass
Treatment performance: Total phosphorus: 
Sum of dissolved phosphorus and insoluble phosphorus
Pass
Treatment performance: Other: 
e.g. e-coli
Not available
Compliance: 
Compliant
Treatment type in place: 
More stringent treatment
Treatment required: 
More stringent treatment : Nitrogen and Phosphorus
Treatment met: 
Yes
Performance met: 
Yes
In cause of failure: Bad operating/Bad design or dimensioning: 
0
In cause of failure: Bad design or dimensioning: 
0
In cause of failure: Further information on cause of failure: 
9589,553306
See diagram

Load and concentration per parameter :

Incoming Discharged Rate
BOD 210.01 t/year 2.02 t/year 99%
473.32 mg/l 4.55 mg/l
COD 477.33 t/year 18.5 t/year 96.1%
1075.79 mg/l 41.69 mg/l
Nitrogen 37.61 t/year 4.33 t/year 88.5%
84.76 mg/l 9.76 mg/l
Phosphorus 4.56 t/year 0.55 t/year 87.9%
10.28 mg/l 1.24 mg/l
* Concentration calculated using the annual load and the annual volume of wastewater treated.
Incoming and discharged loads (t/year)
See the data table
Graphical network summary
Network
Agglomerations : 1 Agglomeration : Salcininkai
(Generated
Network
Network
Entering :
9,500 p.e
Network
N
Network
P
Network
    Main treatment :
  • Network : Compliant
  • Network : Not compliant
  • Network : No information / Not relevant
    More stringent treatment :
    Performance :
  • Network : Pass performance
  • Network : Fail performance
  • Network : Not relevant

    Type :
  • N : Nitrogen removal
  • P : Phosphorus removal
  • UV : UV treatment
  • MICRO : Micro Filtration

    Type :
  • CHLOR : Chlorination
  • OZONE : Ozonation
  • SAND : Sand filtration
  • O : Other more stringent
    Discharge point :
  • Network : Discharge point
  • DCP(S) : Discharge point(s)
Waste Water Network Connexions
Linked agglomeration(s): 
Linked receiving area(s): 
Linked discharge point(s): 
Site information
Characteristics
 54.29380000
 25.39090000
Date of closing: 

Not provided

Explanation for closing: 

Not provided

ID of the successor: 

Not provided

Primary treatment: 
Yes
Secondary treatment: 
Yes
N removal: 
Yes
P removal: 
Yes
UV: 
No
Ozonation: 
No
Sand filtration: 
No
Chlorination: 
No
Micro filtration: 
No
Other treatment: 
No
Other type of more stringent treatment: 

Not provided

Other type of more stringent : 
0
ID of E-PRTR facility: 

Not provided

Accidents: 
No
Remarks: 

Not provided