Agglomeration view on a map with some info UWWTP : Cēsu NAI - Identifier : LV500340 - Status : Active - Connected - Reporting year : 2018 Region (NUTS) Code : LV008 - Region (NUTS) Name : Vidzeme compliance Time Line List of all the year available for the agglomeration 2012201420162018View history Compliant Not compliant Not relevant No information ? Description Load entering UWWTP (p.e.): load expressed in population equivalent shall be calculated on the basis of the maximum average weekly load entering the treatment plant during the year, excluding unusual situations such as those due to heavy rain (Article 4 of the Urban Waste Water Treatment Directive 91/271/CE)20 105Method used to determine the load : Not availableRate of entering load transported to this UWWTP by trucks (%): Not availablePhysical Capacity (p.e.): 30 630Waste water treated (m3/y): Volume of waste water treated and partially treated in the UWWTP1 424 910Method used to determine the volume of waste water treated: MTreatment performance: BOD5: Biological Oxygen DemandPassTreatment performance: COD: Chemical Oxygen DemandPassTreatment performance: TSS: Total Suspended SolidsPassTreatment performance: Total nitrogen: Sum of total kjeldahl nitrogen (organic, ammonia and ammonium), nitrate and nitritePassTreatment performance: Total phosphorus: Sum of dissolved phosphorus and insoluble phosphorusPassTreatment performance: Other: e.g. e-coliNot availableCompliance: CompliantTreatment type in place: More stringent treatmentTreatment required: More stringent treatment : Nitrogen and PhosphorusTreatment met: YesPerformance met: YesIn cause of failure: Bad operating/Bad design or dimensioning: Not availableIn cause of failure: Bad design or dimensioning: Not availableIn cause of failure: Further information on cause of failure: Not available Load and concentration per parameter : Incoming Discharged Rate BOD 440.3 t/year 6.88 t/year 98.4% 309 mg/l 4.83 mg/l COD 1017 t/year 30.61 t/year 97% 713.73 mg/l 21.48 mg/l Nitrogen 81.51 t/year 9.36 t/year 88.5% 57.2 mg/l 6.57 mg/l Phosphorus 11.83 t/year 1.52 t/year 87.2% 8.3 mg/l 1.07 mg/l * Concentration calculated using the annual load and the annual volume of wastewater treated. Incoming and discharged loads (t/year) Graphical network summary Agglomerations : 2 Agglomeration : Cēsis (GeneratedAgglomeration : Priekuļi (Generated Cēsu NAI Entering :20,105 p.e NP 1 DCP(S)Discharge point: GaujaLatvia(A58) Main treatment : : Compliant : Not compliant : No information / Not relevant More stringent treatment : Performance : : Pass performance : Fail performance : Not relevant Type : N : Nitrogen removal P : Phosphorus removal UV : UV treatment MICRO : Micro Filtration Type : CHLOR : Chlorination OZONE : Ozonation SAND : Sand filtration O : Other more stringent Discharge point : : Discharge point DCP(S) : Discharge point(s) Waste Water Network Connexions Linked agglomeration(s): CēsisPriekuļiLinked receiving area(s): LatviaLinked discharge point(s): Gauja Site information Year of data: 2018 Source of data: See sourcefile Other years : Year of data: 2016 Source of data: See sourcefile Year of data: 2014 Source of data: See sourcefile Year of data: 2012 Source of data: See sourcefile UWWTP national Internet hyperlink: Not available Characteristics Latitude : 57.30770000 Longitude : 25.21720000 Date of closing: Not providedExplanation for closing: Not providedID of the successor: Not providedPrimary treatment: Secondary treatment: N removal: P removal: UV: Not availableOzonation: Not availableSand filtration: Not availableChlorination: Not availableMicro filtration: Not availableOther treatment: Not availableOther type of more stringent treatment: Not providedOther type of more stringent : Not providedID of E-PRTR facility: Not providedAccidents: Not availableRemarks: Not provided