Agglomeration view on a map with some info UWWTP : Bodajk - Szennyviztisztito Telep - Identifier : HU-WWTP-AIB641 - Status : Active - Connected - Reporting year : 2014 Region (NUTS) Code : HU211 - Region (NUTS) Name : Fejér compliance Time Line List of all the year available for the agglomeration 20142016View history Compliant Not compliant Not relevant No information ? Description Load entering UWWTP (p.e.): load expressed in population equivalent shall be calculated on the basis of the maximum average weekly load entering the treatment plant during the year, excluding unusual situations such as those due to heavy rain (Article 4 of the Urban Waste Water Treatment Directive 91/271/CE)7 800Method used to determine the load : Not availableRate of entering load transported to this UWWTP by trucks (%): Not availablePhysical Capacity (p.e.): 7 100Waste water treated (m3/y): Volume of waste water treated and partially treated in the UWWTP330 360Method used to determine the volume of waste water treated: MTreatment performance: BOD5: Biological Oxygen DemandPassTreatment performance: COD: Chemical Oxygen DemandPassTreatment performance: TSS: Total Suspended SolidsPassTreatment performance: Total nitrogen: Sum of total kjeldahl nitrogen (organic, ammonia and ammonium), nitrate and nitriteFailTreatment performance: Total phosphorus: Sum of dissolved phosphorus and insoluble phosphorusFailTreatment performance: Other: e.g. e-coliNot availableCompliance: CompliantTreatment type in place: More stringent treatmentTreatment required: Secondary treatmentTreatment met: YesPerformance met: YesIn cause of failure: Bad operating/Bad design or dimensioning: 0In cause of failure: Bad design or dimensioning: 0In cause of failure: Further information on cause of failure: - Load and concentration per parameter : Incoming Discharged Rate BOD 138.09 t/year 1.95 t/year 98.6% 418 mg/l 5.9 mg/l COD 309.45 t/year 12.29 t/year 96% 936.71 mg/l 37.2 mg/l Nitrogen 34.79 t/year 9.08 t/year 73.9% 105.31 mg/l 27.49 mg/l Phosphorus 4.43 t/year 1.59 t/year 64.1% 13.41 mg/l 4.81 mg/l * Concentration calculated using the annual load and the annual volume of wastewater treated. Incoming and discharged loads (t/year) Graphical network summary Agglomerations : 1 Agglomeration : Bodajk - Szennyvizelvezetesi Agglomeracio (Generated Bodajk - Szennyviztisztito Telep Entering :7,800 p.e NP 1 DCP(S)Discharge point: Mor-Bodajki vizfolyas [7.490 fkm] - Kibocsatasi Pont(NA) Main treatment : : Compliant : Not compliant : No information / Not relevant More stringent treatment : Performance : : Pass performance : Fail performance : Not relevant Type : N : Nitrogen removal P : Phosphorus removal UV : UV treatment MICRO : Micro Filtration Type : CHLOR : Chlorination OZONE : Ozonation SAND : Sand filtration O : Other more stringent Discharge point : : Discharge point DCP(S) : Discharge point(s) Waste Water Network Connexions Linked agglomeration(s): Bodajk - Szennyvizelvezetesi AgglomeracioLinked receiving area(s): Not availableLinked discharge point(s): Mor-Bodajki vizfolyas [7.490 fkm] - Kibocsatasi Pont Site information Year of data: 2014 Source of data: See sourcefile Other years : Year of data: 2016 Source of data: See sourcefile UWWTP national Internet hyperlink: Not available Characteristics Latitude : 47.33000000 Longitude : 18.23000000 Date of closing: Not providedExplanation for closing: -ID of the successor: Not providedPrimary treatment: Secondary treatment: N removal: P removal: UV: Ozonation: Sand filtration: Chlorination: Micro filtration: Other treatment: Other type of more stringent treatment: -Other type of more stringent : Not providedID of E-PRTR facility: Not providedAccidents: Remarks: Not provided