OURANOPOLI - history

UWWTP : OURANOPOLI - Identifier : EL1270120548 - Status : Active
Region (NUTS) Code : EL527 - Region (NUTS) Name : EL527

2012

2014

2016

 
Compliant
 
Not compliant
 
Not relevant
 
No information
 
?


Description

YearComplianceTreatment typeLoadTreatment performance
2012Compliance : Not Compliant
Treatment met : Yes
Performance met : No
required : Secondary treatment
in place : More stringent treatment
Capacity:
2,500 p.e.From field <uwwCapacity> : Organic design capacity (p.e.)
Entering:
2,288 p.e.From field <uwwLoadEnteringUWWTP> : Load entering UWWTP (p.e.)
Load rate:
91.5 % <uwwLoadEnteringUWWTP> / <uwwCapacity> x 100
BOD:
FailFrom field <uwwBOD5Perf>
COD:
FailFrom field <uwwCODPerf>
TSS:
FailFrom field <uwwTSSPerf>
Total Nitrogen:
Not relevantFrom field <uwwNTotPerf>
Total phosphorus:
Not relevantFrom field <uwwPTotPerf>
Other:
Not relevantFrom field <uwwOtherPerf>
2014Compliance : Not Compliant
Treatment met : Yes
Performance met : No
required : Secondary treatment
in place : More stringent treatment
Capacity:
2,500 p.e.From field <uwwCapacity> : Organic design capacity (p.e.)
Entering:
2,288 p.e.From field <uwwLoadEnteringUWWTP> : Load entering UWWTP (p.e.)
Load rate:
91.5 % <uwwLoadEnteringUWWTP> / <uwwCapacity> x 100
BOD:
FailFrom field <uwwBOD5Perf>
COD:
FailFrom field <uwwCODPerf>
TSS:
FailFrom field <uwwTSSPerf>
Total Nitrogen:
Not relevantFrom field <uwwNTotPerf>
Total phosphorus:
Not relevantFrom field <uwwPTotPerf>
Other:
Not relevantFrom field <uwwOtherPerf>
2016Compliance : Not Compliant
Treatment met : Yes
Performance met : No
required : Secondary treatment
in place : More stringent treatment
Capacity:
2,500 p.e.From field <uwwCapacity> : Organic design capacity (p.e.)
Entering:
2,288 p.e.From field <uwwLoadEnteringUWWTP> : Load entering UWWTP (p.e.)
Load rate:
91.5 % <uwwLoadEnteringUWWTP> / <uwwCapacity> x 100
BOD:
FailFrom field <uwwBOD5Perf>
COD:
FailFrom field <uwwCODPerf>
TSS:
FailFrom field <uwwTSSPerf>
Total Nitrogen:
Not relevantFrom field <uwwNTotPerf>
Total phosphorus:
Not relevantFrom field <uwwPTotPerf>
Other:
Not relevantFrom field <uwwOtherPerf>

Entering load and design capacity

Entering load vs Physical Capacity (p.e.)
See the data table
Entering load vs Physical Capacity (p.e.)
See diagram
YearEnteringCapacityLoad rate
20122,288 p.e.2,500 p.e.91.5 %
20142,288 p.e.2,500 p.e.91.5 %
20162,288 p.e.2,500 p.e.91.5 %

Agglomerations

  • There are new elements between 2014 and 2016: EL12701205.
  • There are missing elements between 2014 and 2016: GR12701205.
Year
UWWTP capacity
Value define in <uwwCapacity> field for the UWWTP in the report file with definition : "Organic design capacity (p.e.)"
UWWTP Entering load
Value define in <uwwLoadEnteringUWWTP> field for the UWWTP in the report file with definition : "Load entering UWWTP (p.e.)"
Total of load collected by collecting systems and entering the UWWTPs
Sum of load adressed to UWWTP by linked agglomeration. The load addressed by an agglomeration to an UWWTP is calculated with the following formula : Generated load (p.e.) of the agglomeration (<aggGenerated>) x Rate of generated load of agglomeration collected through collecting system (% of p.e.) (<aggC1>) x % of load of agglomeration collected in collecting system and entering that treatmentplant (<aucPercEnteringUWWTP>)
Linked Agglomeration(s) with addressed load to the UWWTP
20122,500p.e.2,288p.e.2,288p.e.
20142,500p.e.2,288p.e.2,288p.e.
20162,500p.e.2,288p.e.2,288p.e.
Notice : "UWWTP entering load" is based on measure of yearly average, "Total of load collected" is based on estimation of maximum over a year.

Discharge points

YearLinked Discharge point(s)
2012
2014
2016