Agglomeration view on a map with some info UWWTP : KATERINI - Identifier : EL125001019 - Status : Active - Connected - Reporting year : 2016 Region (NUTS) Code : EL525 - Region (NUTS) Name : EL525 compliance Time Line List of all the year available for the agglomeration 201220142016View history Compliant Not compliant Not relevant No information ? Description Load entering UWWTP (p.e.): load expressed in population equivalent shall be calculated on the basis of the maximum average weekly load entering the treatment plant during the year, excluding unusual situations such as those due to heavy rain (Article 4 of the Urban Waste Water Treatment Directive 91/271/CE)125 192Method used to determine the load : Not availableRate of entering load transported to this UWWTP by trucks (%): Not availablePhysical Capacity (p.e.): 130 000Waste water treated (m3/y): Volume of waste water treated and partially treated in the UWWTP32 150Method used to determine the volume of waste water treated: Not availableTreatment performance: BOD5: Biological Oxygen DemandPassTreatment performance: COD: Chemical Oxygen DemandPassTreatment performance: TSS: Total Suspended SolidsPassTreatment performance: Total nitrogen: Sum of total kjeldahl nitrogen (organic, ammonia and ammonium), nitrate and nitriteNRTreatment performance: Total phosphorus: Sum of dissolved phosphorus and insoluble phosphorusNRTreatment performance: Other: e.g. e-coliNRCompliance: CompliantTreatment type in place: More stringent treatmentTreatment required: Secondary treatmentTreatment met: YesPerformance met: YesIn cause of failure: Bad operating/Bad design or dimensioning: 0In cause of failure: Bad design or dimensioning: 0In cause of failure: Further information on cause of failure: For the 1% of non-sewered areas where the collecting system has not been constructed, the generated sewage transported to the UWWTP of Katerini. Load and concentration per parameter : Incoming Discharged Rate BOD 145.45 t/year 4524.11 mg/l COD 273.3 t/year 8500.78 mg/l Nitrogen 103.23 t/year 3210.89 mg/l Phosphorus 31.1 t/year 967.34 mg/l * Concentration calculated using the annual load and the annual volume of wastewater treated. Incoming and discharged loads (t/year) Graphical network summary Agglomerations : 4 Agglomeration : KATERINI (GeneratedAgglomeration : SVORONOS (GeneratedAgglomeration : VRONTOU (GeneratedAgglomeration : KARITSA (Generated KATERINI Entering :125,192 p.e NPCHLOR 1 DCP(S)Discharge point: AESSONAS RIVER(NA) Main treatment : : Compliant : Not compliant : No information / Not relevant More stringent treatment : Performance : : Pass performance : Fail performance : Not relevant Type : N : Nitrogen removal P : Phosphorus removal UV : UV treatment MICRO : Micro Filtration Type : CHLOR : Chlorination OZONE : Ozonation SAND : Sand filtration O : Other more stringent Discharge point : : Discharge point DCP(S) : Discharge point(s) Waste Water Network Connexions Linked agglomeration(s): KATERINISVORONOSVRONTOUKARITSALinked receiving area(s): Not availableLinked discharge point(s): AESSONAS RIVER Site information Year of data: 2016 Source of data: See sourcefile Other years : UWWTP national Internet hyperlink: Not available Characteristics Latitude : 40.22256873 Longitude : 22.53618618 Date of closing: Not providedExplanation for closing: Not providedID of the successor: Not providedPrimary treatment: Secondary treatment: N removal: P removal: UV: Ozonation: Sand filtration: Chlorination: Micro filtration: Other treatment: Other type of more stringent treatment: Not providedOther type of more stringent : Not providedID of E-PRTR facility: Not providedAccidents: Remarks: Not provided