Agglomeration view on a map with some info UWWTP : Limassol - Identifier : CY51_UWWTP - Status : Active - Connected - Reporting year : 2018 Region (NUTS) Code : CY000 - Region (NUTS) Name : Κύπρος (Kýpros) compliance Time Line List of all the year available for the agglomeration 2011201420162018View history Compliant Not compliant Not relevant No information ? Description Load entering UWWTP (p.e.): load expressed in population equivalent shall be calculated on the basis of the maximum average weekly load entering the treatment plant during the year, excluding unusual situations such as those due to heavy rain (Article 4 of the Urban Waste Water Treatment Directive 91/271/CE)240 800Method used to determine the load : Not availableRate of entering load transported to this UWWTP by trucks (%): Not availablePhysical Capacity (p.e.): 272 000Waste water treated (m3/y): Volume of waste water treated and partially treated in the UWWTP9 187 840Method used to determine the volume of waste water treated: MTreatment performance: BOD5: Biological Oxygen DemandPassTreatment performance: COD: Chemical Oxygen DemandPassTreatment performance: TSS: Total Suspended SolidsPassTreatment performance: Total nitrogen: Sum of total kjeldahl nitrogen (organic, ammonia and ammonium), nitrate and nitritePassTreatment performance: Total phosphorus: Sum of dissolved phosphorus and insoluble phosphorusPassTreatment performance: Other: e.g. e-coliNRCompliance: CompliantTreatment type in place: More stringent treatmentTreatment required: More stringent treatment : Nitrogen and PhosphorusTreatment met: YesPerformance met: YesIn cause of failure: Bad operating/Bad design or dimensioning: Not availableIn cause of failure: Bad design or dimensioning: Not availableIn cause of failure: Further information on cause of failure: Not available Load and concentration per parameter : Incoming Discharged Rate BOD 4263.4 t/year 24.5 t/year 99.4% 464.03 mg/l 2.67 mg/l COD 9176.95 t/year 256.88 t/year 97.2% 998.81 mg/l 27.96 mg/l Nitrogen 786.5 t/year 150.76 t/year 80.8% 85.6 mg/l 16.41 mg/l Phosphorus 116.51 t/year 14.28 t/year 87.7% 12.68 mg/l 1.55 mg/l * Concentration calculated using the annual load and the annual volume of wastewater treated. Incoming and discharged loads (t/year) Graphical network summary Agglomerations : 4 Agglomeration : Limassol (GeneratedAgglomeration : Agia Phyla (GeneratedAgglomeration : Agios Tychonas (GeneratedAgglomeration : Mouttagiaka (Generated Limassol Entering :240,800 p.e NPCHLORSAND 7 DCP(S)Discharge point: Coastal waters(NA)Polemidia DamCatchment of Polemidia(CSA)Akrotiri Aquifer(NA)Green areas at WWTP(NA)Ypsonas area(NA)Germasogia area(NA)Parekklisia area(NA) Main treatment : : Compliant : Not compliant : No information / Not relevant More stringent treatment : Performance : : Pass performance : Fail performance : Not relevant Type : N : Nitrogen removal P : Phosphorus removal UV : UV treatment MICRO : Micro Filtration Type : CHLOR : Chlorination OZONE : Ozonation SAND : Sand filtration O : Other more stringent Discharge point : : Discharge point DCP(S) : Discharge point(s) Waste Water Network Connexions Linked agglomeration(s): LimassolAgia PhylaAgios TychonasMouttagiakaLinked receiving area(s): Catchment of PolemidiaLinked discharge point(s): Coastal watersPolemidia DamAkrotiri AquiferGreen areas at WWTPYpsonas areaGermasogia areaParekklisia area Site information Year of data: 2018 Source of data: See sourcefile Other years : Year of data: 2016 Source of data: See sourcefile Year of data: 2014 Source of data: See sourcefile Year of data: 2011 Source of data: See sourcefile UWWTP national Internet hyperlink: Not available Characteristics Latitude : 34.71127000 Longitude : 33.21331000 Date of closing: Not providedExplanation for closing: Not providedID of the successor: Not providedPrimary treatment: Secondary treatment: N removal: P removal: UV: Ozonation: Sand filtration: Chlorination: Micro filtration: Other treatment: Other type of more stringent treatment: Not providedOther type of more stringent : Not providedID of E-PRTR facility: Not providedAccidents: Not availableRemarks: The uwwtp entering load in p.e. is calculated on the basis of the max average weekly load based on the use of 24h flows in combination with 24 hour BOD5 samples. Annual loads determined from annual average concentrations and annual volumes. Errors: Not provided